  • Burnham Boilers: Problems Need To Be Fixed Immediately

    Jan 12, 2010 · Burnham boiler problems can be caused by any number of things. One of the greatest concerns with any boiler is leaking water. You need to pay special attention to your boiler and at the first sign of any leak make sure to call a professional serviceman immediately. A small leak on a boiler is the first indication of a much larger issue and Get Price

  • Ripoff Report | U S Boiler Co. Review - Lancaster

    I am on my 3rd Burnham boiler in 10 years I had a V7 steam boiler installed in May 1999 the boiler failed in July 2003 under warranty It was replaced with what Burnham called the V8 that had addressed the V7 problems. I got no help with the intsall of the new boiler and was out $1500. to install the new V8, In March 2009 the V8 also failed int Get Price

  • Atlas V14 Full Crack |VERIFIED| 14 | Peatix

    But, do I have a Burnham Steam Boiler (residential) It is a V-74 Serial climate change in this area Standard atlas of Manistee County, Michigan : including a plat of the United States Thursday, June 14, 1951 1951 CLASSIFIED ADS continued atlas v14 full crack download broken beats by dre detox serial number keygen sound forge pro 11 Get Price

  • Burnham oil boiler cracked block leaking - YouTube

    Burnham boiler leaking at common spot, poor casting defectGet Price

  • Burnham V7 Boilers - Furnace Compare

    Mar 13, 2019 · Burnham V7 Boiler Overview. The Burnham V7 is a discontinued oil-fired boiler with an AFUE of up to 86.2%. The V7 was configured for steam or hot water heating and was available as a fully-packaged or a knockdown unit. The cast iron sections and vertical flue were designed to extract the maximum amount of heat and maintain low draft losses.Get Price

  • Boiler Cracked? How to tell? - HVAC-Talk: Heating, Air

    Dec 12, 2007 · Hi, I just bought a house with forced hot water heating. It has a Burnham V7 series hot water boiler. The house is 14yrs old and I assume the boiler is original to the house. The home inspector told me that the boiler requires yearly service so I called a company to come out. They told me that the boiler was cracked and needed to be replaced.Get Price

  • Burnham V7 boiler big problem!! - DoItYourself.com

    Sep 27, 2007 · Burnham V7 boiler big problem!! My boiler installed in 1999 is now leaking. I was turned down by burnham for any help because I am not the original home owner (we all know how hard changing owners can be on a boiler). My internet research shows that Burnham knew this problem existed and it has happen to a ton of people with the V7's.Get Price

  • Leaking Burnham V7 series boiler — Heating Help: The Wall

    April 2013. leaking v7 and v8 series. I own a boiler removal company and since 1997 I have removed over 4000 Burnham v7 in v8 series boilers. I know many of the warranty question answers. Feel free to call me at 617 733 8597. My name is Dennis, happy to help in any way.Get Price

  • Re: Burnham V7 crack problem

    Re: Burnham V7 crack problem [ Follow Ups] [ Post Followup] [ Boiler Room Residential and Home Forum #2] [ FAQ] I also had a Burnham V73 boiler that cracked. It turns out that there is a KNOWN manufacturing defect with that boiler. Burnham nevered issued a recall. Instead, they replaced the boiler under the 10 year warranty.Get Price

  • US Boiler Recalls Home Heating Boilers | CPSC.gov

    Jan 09, 2014 · Consumers with recalled boilers should immediately contact the installer or distributor from whom they purchased the boiler or U.S. Boiler to schedule a free in-home safety inspection and repair. Consumers who continue use of the boilers while awaiting repair, should have a working carbon monoxide alarm installed outside of sleeping areas in the home.Get Price

  • Burnham V7 crack problem - The Boiler Room at

    In Reply to: Burnham V7 crack problem posted by margit price on February 07, 2005 at 13:18:01: Me too - it's a current problem, leaking from the bottom of the firebox - which fills up with water at a fairly rapid, regular pace. Also my neighbor just went through the same thing and his boiler was only 6 years old.Get Price

  • Hot water boiler-Domestic coil disconnect - DoItYourself

    Aug 05, 2009 · We had a defective v7 boiler thst cracked. It got replaced with another v7 block that also cracked. Burnham sent us a v8 and we had to pay for installation. Guess whatit cracked. We then went through this 2 more times. Now having a problem again. We followed all Burnham recommendations for the last install..very expensive.Get Price

  • Burnham V7 oil-fired boiler with tankless coil : hvacadvice

    Burnham V7 oil-fired boiler with tankless coil Hi, We are at our wit's end with this Burnham V7 oil boiler inherited from the previous owner. I can some pictures but here's my question - based on what you can see, will a coil replacement be enough?Get Price

  • Burnham Boiler Reviews 2021 Quality Efficiency Ratings

    Jul 05, 2015 · Most Burnham boilers are gas-fired, but Burnham does have oiled-fired boilers. While the fuel changes from gas to oil, the efficiency rating is decent for the oil boiler. Rated at 87% AFUE, Burhham's MPO-IQ oil-fired boiler is for people who use oil for heating fuel. It is a three-pass boiler for added efficiency.Get Price

  • Outdoor Reset & Thermal Shock w/ Old Oil Boiler?

    Oct 19, 2009 · We're trying to figure out if adding a Tekmar outdoor reset controller to our Burnham V74-T oil fired boiler makes sense. It's a baseboard hot water system, and I'm assuming the boiler is presently set up to maintain a peak 180 degree water temperature. I like the concept of outdoor reset, but if the minimum temperature the boiler wants to see isn't that far below the …Get Price

  • Knockdown Boiler Assembly - Burnham V7 SERIES Operating

    Burnham V7 SERIES manual : Knockdown Boiler Assembly. Burnham V7 SERIES manual : Knockdown Boiler Assembly. Manualsbrain.com. Sign in. en. Deutsch; (O pt iona l Re tu rn ) R etur n. H. 1½ " R etur n. B us he d to ¾ " for Dr ainc oc k (O pt iona l Re tu rn ) J. 1½ " S u rfac e B low of f - Plu g ge d Get Price

  • Burnham warning from home owner. — Heating Help: The Wall

    Learn from my mistake and avoid Burnham at all costs. My V7 series residential oil fired water boiler is leaking after only 5 years in service. Much research on this board and other related forums (and Burnham yearly financial report under liabilities)aknowledge Burnham had a manufacturing problem leading to product failure.Get Price

  • Burnham V7 boiler big problem!! - DoItYourself.com

    Sep 27, 2007 · Burnham V7 boiler big problem!! My boiler installed in 1999 is now leaking. I was turned down by burnham for any help because I am not the original home owner (we all know how hard changing owners can be on a boiler). My internet research shows that Burnham knew this problem existed and it has happen to a ton of people with the V7's.Get Price

  • Burnham Boiler Reviews | FurnaceCompare

    Jan 23, 2020 · Cast Iron Gas Boiler. Burnham's cast iron, natural or LP gas boilers have models appropriate for homes with or without chimneys. The AFUE ratings range from 80 to 85 percent. Those with an 84- to 85-percent rating are Energy Star-qualified products. These well-insulated heat exchangers come with the Intelligent Hydronic Control System, which Get Price

  • Burnham V7 crack problem - The Boiler Room at

    In Reply to: Burnham V7 crack problem posted by margit price on February 07, 2005 at 13:18:01: Me too - it's a current problem, leaking from the bottom of the firebox - which fills up with water at a fairly rapid, regular pace. Also my neighbor just went through the same thing and his boiler was only 6 years old.Get Price

  • Have a v74 Model Burnham Hydronic Boiler installed in 08

    Dec 11, 2012 · Downloaded the v7 Burnham engineering/maint PDF years ago. Should be able to find the v8 as well. Customer: Not in my area but we're out of the storm zone. Customer: About 160 days ago i asked a question about my cracked Burnham steam boiler thas is supposed to have a 10 year warranty on the cast block. After only 6 in service years, it Get Price

  • Burnham MPO IQ147 or Weil Mclain WGO3 — Heating Help: The …

    I had a Burnham V7 Boiler installed in 1999 it failed after four years Burnham replaced the block with a V8 block now the V8 block cracked in exactly the same place that the last block cracked, the middle section near the clean out access about half way high on the section. My home is 2400 sq ft. Hydro air system two heating zones and a third zone for DHW.Get Price

  • Burnham KIN9LNI-LE2 KIN9LNILE2 KIN9LNI Independence

    Burnham KIN9LNI-LE2 KIN9LNILE2 KIN9LNI Independence 174,000 BTU KnockDown Steam Boiler NG Gas Fired, Chimney or Power Vented, Cast Iron Steam Boiler. Burnham's Independence PV boilers offer you the flexibility of a power vent system. This boiler can be installed virtually anywhere because no chimney is required for operation.Get Price

  • Burnham V7 crack problem - The Boiler Room at

    Burnham did pay $500 of the $1600 that it cost to remove and install the new boiler, but given the fact that Burnham knowingly distributed thousands of faulty boilers without issuing a recall, I plan to persue the remainder of the labor cost through other means. Re: Burnham V7 crack problem michael earley 21:59:38 12/04/2006 (0) Re: Get Price

  • Burnham V7 Rebate or Block Replacement - DoItYourself.com

    Apr 24, 2009 · Boilers - Home Heating Steam and Hot Water Systems - Burnham V7 Rebate or Block Replacement - My 12 year old Burnham V7 is leaking due to casting flaw. If it was still under warranty, Burnham would have provided a replacement V7 Heat Exchanger (Block). Not being under warranty, Burnham is offering a $750 rebate if IGet Price

  • About 160 days ago i asked a question about my cracked

    Aug 28, 2012 · About 160 days ago i asked a question about my cracked Burnham steam boiler thas is supposed to have a 10 year warranty on the cast block. After only 6 in service years, it cracked. The company I have the service contract with confirmed this. They now want to install a Peerless boiler to replace the cracked Burnham at a cost of $5800.Get Price

  • glenn stanton @ burnham MPO147

    Jul 07, 2007 · I had a service technician from my oil company come out today to give my Burnham V-83 oil-fired boiler its annual tuneup. He ended up not doing the tuneup, because he told me that I had a "cracked boiler" and there was no sense in tuning up something that was broken. I was just annoyed since the boiler is 6 years old.Get Price

  • Re: BURNHAM V7 CRACKED BOILER

    Posted by Jeremy Pippenger on April 21, 2008 at 12:16:42:. In Reply to: Re: BURNHAM V7 CRACKED BOILER posted by Aaron D. Osgood on April 02, 2008 at 13:40:42: I have the same exact issue as well. I am furious. The Orginal V7 boiler was installed in 1998. It cracked in late 2004 and the replacement cracked AGAIN in April 2007.Get Price

  • Amazon.com: burnham boiler

    BURNHAM 801601158 "EC5000" 4-ZONE BURNHAM ENERGY BOILER CONTROL PACKAGE. $847.00. $847. . 00. Get it Thu, Nov 4 - Wed, Nov 10. FREE Shipping. Burnham ALP210BW-4T02 210,000 BTU"Alpine Series" Stainless Steel MODULATING CONDENSING HIGH Efficiency Direct Vent Natural Gas HOT Water Wall Mount Boiler/W SAGE 2.1 Boiler Control System 95%. …Get Price

  • Burnham Boiler Reviews | FurnaceCompare

    Jan 23, 2020 · Cast Iron Gas Boiler. Burnham's cast iron, natural or LP gas boilers have models appropriate for homes with or without chimneys. The AFUE ratings range from 80 to 85 percent. Those with an 84- to 85-percent rating are Energy Star-qualified products. These well-insulated heat exchangers come with the Intelligent Hydronic Control System, which Get Price

  • Residential Boiler Heating Products | U.S. Boiler Company

    Residential Boiler & Product Selector. When you purchase a boiler in U.S. Boiler Company's extensive line, you know you're getting the best in comfort, durability and safety. With five models meeting the ENERGY STAR efficiency standards, we have the right boiler for your home heating needs! Show All Products.Get Price

  • Model number 3WRH burnham 20 years old Problem: Boiler

    Feb 06, 2016 · Re Burnham oil fired boiler serial # 8142819R2 installed approx Re: Burnham oil fired boiler serial #(NNN) NNN-NNNN installed approx Nov, 2008 in area code 15622. The boiler was smoking and spewing soot over itself, since mostly corrected.Get Price

  • Ripoff Report | Burnham Boiler complaints, reviews, scams

    Jan 04, 2016 · Burnham (U.S Boiler Company) steam home boiler ) Two bad Burnham steam boilers in 22 years. Second one installed around 2006 now cracked and needs replacing again. This will be the third boiler in 23 years. Lancaster PennsylvaniaGet Price

  • Burnham V7 Boilers - Furnace Compare

    Mar 13, 2019 · Burnham V7 Boiler Overview. The Burnham V7 is a discontinued oil-fired boiler with an AFUE of up to 86.2%. The V7 was configured for steam or hot water heating and was available as a fully-packaged or a knockdown unit. The cast iron sections and vertical flue were designed to extract the maximum amount of heat and maintain low draft losses.Get Price

  • Burnham boiler block leak and I have to pay install charges

    Mar 28, 2006 · Paying for labor on a warrantee block replacement is part of owning a V7 Burnham boiler. Look at this way, for probably less than 500 'clams' you get a new boiler block, the heart of the unit. All the V7 blocks are bad, it's only a matter of time before they leak, so be glad it did it in 6 yrs where you're given a free block.Get Price

  • Smaller nozzle in Burnham boiler? - DoItYourself.com

    Jan 07, 2010 · All Burnham oil fired products be it commercial or residential look for 11.5% - 12.5 CO2 and negative draft boilers are looking for an OF draft of -0.01 to - 0.02 which include the V7, V8, RSA and the "C" series boilers.Get Price

  • Burnham V-7 boiler leaking water - HVAC-Talk: Heating, Air

    Nov 25, 2008 · I have 1997 Burnham boiler model number PV73WBT that is leaking water from a crack in the first cast iron plate. I believe this is called a triple pass unit. Can just the 1 plate be replaced or does the whole unit need to be changed out?Get Price

  • Burnham Boiler Section Cracking free download - lloaddcloud

    Nov 07, 2015 · Burnham Boiler Section Cracking Cards. Read 10 reviews of BURNHAM boilers written from Jan 2014 to Aug 2015 or write your own review. We had a defective v7 boiler thst cracked. It got replaced with another v7 block that also cracked. Burnham sent us a v8 and we had to pay for. Consumer Reviews of BURNHAM boilersGet Price

  • I need to replace a Burnham V-7 Oil fired boiler, do I

    We purchased a new Burnham V7 oil furnace 6 years ago from a local dealer. There is a 10 year limited warranty on the system but no one will help to replace the cracked/leaking cast iron boiler. The m … read moreGet Price

  • Burnham V7 occasional "hard lockout" — Heating Help: The Wall

    Apr 29, 2021 · Burnham V7 that experiences occasional "hard lockout" on the controller LCD display. Boiler then gets cold as the home is not occupied full time. This appears to be an ignition issue as I can reset the controller and it will fire up, first try. There will be an odor and sometimes a puff of smoke from the flame inspection port on light off Get Price

  • Burnham water coil cover plate replacment. Rusty

    Aug 06, 2020 · Burnham has never had a boiler section made in china. They did have issues with the V7 due to increasing the input and too sharp of a radius on the block. They would crack near the boiler clean-out. The block was not any thinner than any others. The early V8's had nipple problems around 2000 - 2003 when they were farmed out to a local machine shop.Get Price

  • Re: Burnham V7 crack problem II - The Boiler Room at

    I have made the observation among consumers and professionals that the V7 is known to crack at a premature age, leak and eventually require replacement. Since it seems that so many consumers and distributors have witnessed Burnham's refusal to 1) have recalled the product or 2) pay according to warranty, I have begun pursuing a class action suit through Alexander, …Get Price

  • Burnham V-7 furnace leaking water | DIY Home Improvement Forum

    Nov 29, 2008 · I have a 1997 Burnham V-7 furnace Model number PV73WBT. Upon removal of the side panels, there is a crack in the first cast iron plate which is leaking in this thread in this sub-forum in the entire site. He will get a new V7 block unless it is a steam boiler than a V8. He can swing a deal on a new V8 or MPO if a water boiler.Get Price

  • I have a Burnam boiler installed in 2004 (Model #3WNH). In

    Dec 24, 2014 · The boiler burners should be taken out and with an inspection mirror, look up in the burner area (heat exchanger). Sooting is common on boilers due to the compactness of the unit. This can cause hot spots and even a cracked heat exchanger. Once cracked, weird things can happen such as what you mention.Get Price

  • Knockdown Boiler Assembly - Burnham V7 SERIES Operating

    Burnham V7 SERIES manual : Knockdown Boiler Assembly. probe into ¾" tapping located on the front section directly above the protectorelay on the oil burner.Get Price

  • Burnham Boiler Parts, buy OEM burnham boiler parts online

    Burnham Boiler Fasco Motor 1/10HP 115v 3200 RPM 7062-3101 8116142 D405 This is a brand new Original Equipment Manufacturer (OEM) Burnham Boiler Fasco blower motor 1/10hp 115 volt 3200rpm, part# D405. Included with the motor, is a matching 10 MFDGet Price